美国ENTECH公司是一家专业VOCs采样系统生产商。拥有目前全球最先进的最丰富气体采样设备生产经验,尤其是在苏码罐的经验,专利的SiloniteTM技术是被公认为最为先进的硅烷化技术之一。随着人们对日益恶化环境的关注程度不断增加,与大家最直接的环境大气和室内空气中的VOCs倍受关注。目前众多的采样方法中,公认真空苏码罐采样最准确最有效的采样方式之一。多年来ENTECH一直在这个领域处于领先地位,开发的产品种类之多,应用广泛,占据全球90%以上的市场。
Solutions for Analyzing Volatiles in Solids, Liquid and Gases
Volatile chemicals can be analyzed using a variety of techniques from qualitative, non-specific detectors to very reliable and quantitative GC and GCMS methods. In many cases, remote sample collection and laboratory analysis have several advantages over on-site analysis. Simple, rugged samplers allow the collection of gas, liquid or solid samples without the need for power, field calibration or highly experienced technicians. Collecting the sample without modification in the field eliminates the chance of losing important analytes, as can occur with adsorption tubes. Samples can be collected from several locations and then analyzed on the same laboratory instrument. The result is lower overall costs and elimination of inter-instrument bias.
Entech has been perfecting the art and science of quantifying levels of volatile chemicals in gas phase matrices from % levels to well below 1 PPB. A new surface coating called SiloniteTM allows stainless steel sampling containers, transfer lines and connective fittings and valves to be rendered as inert as fused silica, greatly extending the range of compounds that can be collected in the field. With Silonite coated canisters, compounds can be analyzed up to several weeks later with very little change in gas phase concentrations. Turn key solutions are available for field sampling into vacuum tight Silonite coated canisters, laboratory analysis using multi-position autosamplers and cleanup systems that allow the coated canisters to be re-used hundreds of times.
The introduction of Large Volume Static Headspace (LVSH) in 1999 has created a powerful new tool for analyzing volatiles in the headspace above solid and liquid samples. The static nature of the analysis eliminates the aerosols and foaming associated with dynamic headspace analysis, while lowering detection limits 100-500 times below conventional loop-injection headspace inlets. Combined with the inertness of Silonite coating and Entech's 14 years of experience in preconcen-tration technology, LVSH is allowing a more complete analysis of foods, flavors, odors and out-gassing contaminants than ever before.
Entech's Contributions to the Science of Chemical Sampling and Analysis:
1990
First whole air multi-position VOC inlet
1992
First 3-stage preconcentrator for polar/non-polar VOC analysis
1993
Turnkey solutions for air analysis
1994
SmartLab 1 systems introduced
1998
Silonite coated minican introduced
1999
Large Volume Static Headspace
2002
New products for semi-volatile sampling and analysis (flavors, fragrances, chemical weapons, mVOC's)
Silonite coated GC injection liners and fittings
USB based SmartLab 2™ introduced
2003
First Robotic Autosampler for canisters and Large Volume Headspace
Direct on-column large volume GC injector for gas phase samples