Hot and Cold Stages for Upright Microscopes
Model
Temperature Range
Sample Chamber Area
Feature
WS60
ambient to 60°C
(95°C Optional)
25 x 75 mm (1 x 3")
and/or 60mm diameter
Compact size warm stage for 1" x 3" slides or 60mm petri dishes.
TS62
-30°C to 120°C
38 x 50 mm
(1.5 x 2")
Peltier based thermal stage for moderate temperature range applications.
TX102W
-30°C to 100°C
38 x 50 mm
(1.5 x 2")
Peltier based microscope thermal stage featuring a wide incident angle (60°) and a large viewing window (38mm dia).
TS104
-30°C to 90°C
90 x 90 mm
(3.6 x 3.6")
Peltier based thermal stage features extra-large sample area.
HCS302
-190°C to 400°C
38 x 50 mm
(1.5 x 2")
Single-heater thermal stage with wide temperature range for general purpose applications. Stage frame cooling using circulation water pump.
HCS402
-190°C to 400°C
38 x 50 mm
(1.5 x 2")
Dual-heater thermal stage, with heaters located both below and above the sample chamber for ultra temperature uniformity. Can be quickly converted to HCS302, the single-heater stage model. Stage frame cooling using circulation water pump.
HCS412W
-60°C to 400°C
38 x 50 mm
(1.5 x 2")
Dual-heater heating and cooling stage features large viewing aperture and wide incident angle.
FS1
-60°C to 200°C
38 x 50 mm
(1.5 x 2")
Dual-heater heating and cooling stage with large viewing aperture for thin film study. Includes thin film drawing kits with removable inner chamber for cleaning.
HS400
ambient to 400°C
38 x 50 mm
(1.5 x 2")
Dual-heater hot stage with ultra temperature uniformity. Built-in fan for air-cooling of the stage frame.
HCS410
-60°C to 400°C
38 x 50 mm
(1.5 x 2")
Dual-heater hot and cold stage, using the built-in fan for frame cooling. Similar to HS400, but also with sample chamber cooling capability.
HCS601
-190°C to 600°C
(700°C optional)
20 x 20 mm
(0.8 x 0.8")
Ultra high temperature hot and cold stage, with the option to extend to wider temperature range.
FCS611
-190°C to 600°C
20 x 20 mm
(0.8 x 0.8")
Ultra high temperature hot and cold stage systems with gas tight sample chamber, features eight (8) electric feed-through leads for sample probing.
FCS612
-190°C to 600°C
38 x 38 mm
(1.5 x 1.5")
HCS206
-40°C to 200°C
139 x 147 mm
(5.5 x 5.8")
Hot and cold stage designed for extra-large samples. Optional circulation water pump for frame cooling.
Hot and Cold Stages for Inverted Microscopes
Model
Temperature Range
Sample Chamber Area
Feature
HCS60
5°C to 60°C
35mm diameter
Peltier based thermal stage designed especially for inverted microscopes. Accepts 35mm petri dishes.
TSA02i
-25°C to 60°C
(90°C upper limit optional)
53 x 78 mm
Peltier based thermal stage features a large viewing aperture and large sample area. Accepts 2"x3" slides.
HCD301
-80°C to 250°C
25 x 25 mm
(1 x 1")
Hot and cold stage specifically designed for use on inverted microscopes with a wide temperature range.