测量原理 | 科氏力 |
主要特点 | 平衡单管测量系统,“Fit-and-Forget”安装方式;易于清洁、卫生、抗化学腐蚀
|
特点 | S-DAT,确认,快速设定,1个累加器
|
Transmitter features | Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
|
直径 | "DN 8...80,5/16"...3"
|
Wetted materials | Measuring tube: Titanium grade 9 Connection: Titanium grade 2
|
Measured variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density
|
测量误差 | 质量流量:±0.2 %,体积流量:±0.5 %
|
量程 | 0...180'000 kg/h
|
压力范围 | PN 16...100,Cl 150...600,JIS 10...63K
|
过程温度 | -50...+150℃
|
环境温度 | Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F)
|
Sensor housing material | 1.4301/1.4307 (304L), corrosion resistant
|
Transmitter housing material | Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast
|
电子插件的防护 | IP 67 NEMA 4x
|
显示/操作 | 两行背光显示,按键操作
|
输出 | 4...20 mA 脉冲/频率,状态
|
输入 | 状态
|
通信 | HART、PROFIBUS PA
|
Power supply | DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz)
|
防爆认证 | ATEX、FM、CSA
|
Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL PED, CRN 3-A, EHEDG
|
Product safety | CE, C-tick, EAC marking
|
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
|
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
|
Pressure approvals and certificates | PED, CRN
|
Material certificates | 3.1 material
|
Hygienic approvals and certificates | 3-A, EHEDG |